Welcome Guest from United States
Sign In Change Country
  0 Items
Search:
GENESYS 10 UV Spectrophotometer

  GENESYS 10 UV Spectrophotometer



The GENESYSTM 10 series spectrophotometers deliver accurate, reliable results while setting new standards for productivity in the lab. Each features a user-friendly interface and rugged reliability that ensures reproducible results, all at an affordable price.



This product is no longer offered.
   Product Detail


Meet the New Laboratory Standard
Researchers, scientists and technicians worldwide depend on Thermo Fisher Scientific to provide UV-Visible spectrophotometers to suit their specific applications and needs. We are pleased to offer the new laboratory standard, the GENESYSTM 10 spectrophotometer.

Powered to Perform, Priced to Surprise
GENESYS spectrophotometers have long been known as the dependable choice for busy laboratory environments. The GENESYS 10 gives you all the features you have come to expect from a GENESYS spectrophotometer including a rugged design, a user-friendly interface and unrivaled reliability. The GENESYS 10 also provides the functionality of an expensive spectrophotometer at an affordable price. Both the Visible and UV-Visible GENESYS 10 models feature a powerful optical design, flexible sample handling and versatile software capabilities that make the GENESYS 10 the smart choice for testing water and waste-water, inorganics, food and beverages, as well as quality control of chemicals or life science applications.

GENESYS 10 UV-Visible spectrophotometers truly are powered to perform and priced to surprise!

High-Quality Optics for High-Performance Results
High-quality optics are absolutely essential for obtaining accurate and precise spectrophotometric measurements. Both GENESYS 10 models utilize a unique optical design that dramatically reduces stray light and produces a precisely focused image on the sample. This imaging allows the use of microcells without special cell holders and ensures the accuracy of your results every time.

The GENESYS 10 UV-Visible model features a xenon flashlamp and dual detectors for an outstanding signal-to-noise ratio. The xenon lamp flashes only when needed during measurements resulting in extended lamp life and lower operating costs. An added benefit of the xenon lamp is its distinct and uniform emission lines that allow wavelength accuracy and resolution to be verified across the wavelength range. Do you need quick, accurate measurements? The GENESYS 10's high-performance optics will do the work for you!

An optional, built-in, 3" (76.2 mm) wide printer documents all parameters including time and date, test name, data and final results. It displays graphs, statistics and sample number – perfect for Good Laboratory Practice (GLP) requirements.

A large graphical display allows easy viewing of instrument conditions and results.

Thanks to a small instrument footprint, you have plenty of room for other lab equipment.

Six-Position Cell Holder models hold a blank and up to five samples in 10mm square cuvettes or (10 mm or 1/2") test tubes. The standard turret will measure all six positions automatically or can be rotated to specific positions by pressing the cell changer buttons. The powerful optics of the GENESYS 10 even allow you to measure 70µL without a special holder.

Routine Absorbance and Transmittance measurements can be determined from the instrument's main screen using a very simple 3-step process. Concentration measurements only require two additional steps: measuring and entering the concentration of the standard.

Simple keyboard-based operation and "Softkeys," specific to each screen, simplify setting up the instrument with your laboratory's test parameters.

Cell changer buttons rotate samples into position.

Cleanable, chemical-resistant surfaces and rugged design make the GENESYS 10 the ideal choice for harsh laboratory environments.

 GENESYS 10 UV Spectrophotometer
 Product# Price  Supplied Cell Holder
     
 335902000      -    Single Cell Holder
 335902A000      -    Single Cell Holder
 335902P000      -    Single Cell Holder
 335902AP000      -    Single Cell Holder
 335903000      -    6-Position Auto Turret
 335903A000      -    6-Position Auto Turret
 335903P000      -    6-Position Auto Turret
 335903AP000      -    6-Position Auto Turret
 33590202      -    Single Cell Holder
 335902A02      -    Single Cell Holder
 335902P02      -    Single Cell Holder
 335902AP02      -    Single Cell Holder
 33590302      -    6-Position Auto Turret
 335903A02      -    6-Position Auto Turret
 335903P02      -    6-Position Auto Turret
 335903AP02      -    6-Position Auto Turret
 33590204      -    Single Cell Holder
 335902A04      -    Single Cell Holder
 335902P04      -    Single Cell Holder
 335902AP04      -    Single Cell Holder
 33590304      -    6-Position Auto Turret
 335903A04      -    6-Position Auto Turret
 335903P04      -    6-Position Auto Turret
 335903AP04      -    6-Position Auto Turret
Product Contact
 Sales Contact
  Service Contact
 
Specifications:
Wavelength Range :190-1100 nm
Wavelength Accuracy :±1.0 nm
Wavelength Repeatability :±0.5 nm
Spectral Bandwidth :5 nm
Optical System :Split-beam
Photometric Range :-0.1 to 3.0A; 0.3 to 125%T; 0 to 9999C
Photometric Accuracy :0.5% of reading, or 0.005A (whichever is greater) up to 2A
Photometric Readout :Absorbance, %Transmittance, Concentration
Lamp Source :Xenon Lamp
Detector :Solid-state detector
Monochromator :Grating-based (1200 lines/mm)
Noise (peak-to-peak @ 340nm) :≤0.001A at 0A; ≤0.002A at 2A
Drift after warmup :≤0.001A/hr
Stray Light (at 220, 340 & 400 nm) :≤0.1%T
Display :320 x 240 pixel backlit LCD, 3.8" x 2.8" alphanumeric/graphic
Supplied interface :RS232c
Test Storage :Up to 40 sets of test parameters
Data Storage :external via RS232c
Languages :English, French, German, Italian, Spanish
Power Requirements :100-240V, 50/60Hz
Dimensions :33cmW x 41cmD x 23.5cmH (13"W x 16"D x 9"H)
Weight :19 lbs (8.6 Kg)
Warranty :1 year
Included with product :Operator's Manual; Dust cover